California Instruments 801RP Series Manuel d'utilisateur Page 197

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 223
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 196
MX / RS Series SCPI Programming Manual AMETEK Programmable Power
MX / RS Series 197
8.10 OMNI Reference Impedance
The OMNI remote programming syntax is part of the Output subsystem.
Subsystem Syntax
OUTPut
:OMNI
[:STATe]<state> Select the OMNI state (BYPassed|ENGaged)
OUTPut:OMNI[:STATe]
This command will engage or bypass the OMNI impedance network. The output voltage will
drop when the state changes.
Command Syntax OUTPut:OMNI[:STATe]<state>
Parameters BYPassed | ENGaged
*RST Value BYPassed
Examples OUTP:OMNI ENG
Query Syntax OUTPut:OMNI[:STATe]?
Returned Parameters BYP|ENG
Related Commands None