California Instruments 801RP Series Spécifications Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 126
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
Parameter
Specification
Frequency
2003RP:
2003RP-HV:
16.0 - 5000 Hz (see Figure 2-1)
Maximum output voltage available from 45 Hz and
up. Maximum voltage derates from 100% at 45 Hz
to 35% at 16 Hz.
2003RP-AV:
360.0 - 5000 Hz (see Figure 2-1)
Resolution:
0.01 Hz from 16.00 to 80.00 Hz
0.1 Hz from 80.1 Hz to 800.0 Hz
1 Hz from 801 Hz to 5000 Hz
Accuracy:
0.02% of programmed value
Temperature
coefficient:
± 5 ppm per degree Celsius
Stability:
± 15 ppm per year
Impedance
Steady State:
(voltage range * 0.0005) / load current.
Figure 2-1: Available RMS Current as function of Output Voltage and Frequency.